Air Compressor Wear Condition Detection
Favorites
Description

The air compressor cylinder meter detects the cylinder wear condition. If the cylindricity error is greater than 0.25 mm and the roundness error is greater than 0.08 mm, honing should be performed. When honing, it should be carried out according to the repair size, generally divided into five levels, each step is increased by 0.25mm.
When the cylinder is honed to the final level of repair, it can be re-inlaid and repaired. When inserting the sleeve, the interference of the fit should be 0.05mm~0.12mm.